By the end of this chapter, you will be able to:
Mastering these skills ensures the Heart Lung machine works reliably, helping save lives during critical surgeries.
The heart lung machine, also known as the cardiopulmonary bypass machine, plays a pivotal role in open-heart surgeries performed in Kenyan hospitals and specialized cardiac centers. This equipment temporarily takes over the functions of the heart and lungs during surgery, ensuring continuous circulation and oxygenation of blood. For biomedical engineers maintaining this sophisticated device, understanding its functions is essential to guarantee patient safety and surgical success. The following sections explain the core functions of the heart lung machine and their relevance in the clinical setting.
In the context of biomedical engineering in Kenya, particularly in major hospitals like Kenyatta National Hospital and private cardiac units, the heart lung machine’s functions must be meticulously maintained. These functions are critical for supporting life during cardiac procedures where the heart must be stopped or its function impaired. The machine’s ability to oxygenate blood, maintain circulation, regulate temperature, and remove carbon dioxide highlights its complexity and the need for precise maintenance protocols.
The primary function of the heart lung machine is to replicate the pumping action of the heart, ensuring continuous blood circulation throughout the body during surgery. This is achieved by a mechanical pump that moves blood from the patient’s venous system to the arterial system, bypassing the heart.
Maintaining the pumping function requires careful calibration to ensure blood flow matches the patient’s metabolic needs. For example, during a coronary artery bypass surgery at a county hospital, the biomedical engineer must verify pump speed and volume settings to prevent complications such as low perfusion or excessive pressure that could damage blood vessels.
Another critical function is oxygenating the blood and removing carbon dioxide, substituting for the lungs during surgery. This is accomplished through an oxygenator component within the machine.
In practice, a biomedical engineer at a Nairobi private hospital ensures the oxygenator membrane is intact-free from clots or damage, and that gas supplies are uninterrupted. Failure in oxygenation can lead to hypoxia, jeopardizing patient outcomes during cardiac surgery.
The heart lung machine also regulates the temperature of the circulating blood to assist in protecting organs and tissues during surgery. Hypothermia induced by cooling reduces metabolic demand, while rewarming prepares the patient for normal physiological function post-surgery.
For instance, during a valve replacement procedure at a county referral hospital, the biomedical engineer collaborates with perfusionists to set temperature parameters that minimize ischemic injury to organs. Proper maintenance of heat exchangers is vital to avoid thermal regulation failures.
Besides oxygen delivery, the heart lung machine removes carbon dioxide from the blood and filters out microemboli and debris that may occur during surgery.
In clinical settings such as at a university hospital, biomedical engineers ensure that filters are replaced regularly and bubble detectors are calibrated to prevent air embolism, a potentially fatal complication. Proper CO2 removal maintains acid-base balance and respiratory homeostasis during cardiopulmonary bypass.
Create a free account to open more of this chapter.
Free: practical guides, quick cards, workplace scenarios and more.
Create a free accountThis chapter explored the functions of the heart lung machine, highlighting its critical role in temporarily taking over the functions of the heart and lungs during cardiac surgery to maintain circulation and oxygenation. The main parts of the machine were examined, including the pump, oxygenator, heat exchanger, and control systems, each essential for effective operation. The principle of operation was discussed, focusing on how the machine circulates and oxygenates blood outside the patient’s body while regulating temperature. Fault diagnosis techniques were presented to identify common mechanical and functional issues that can arise during use. Detailed maintenance procedures were outlined to ensure the machine remains reliable and safe, emphasizing routine checks and component servicing. Safety procedures were stressed throughout the chapter, underscoring protocols to protect both the patient and the medical team. Specifications and recommended equipment ratios for training purposes were also included to support proper handling and skill development. Overall, the chapter provided comprehensive guidance on maintaining the heart lung machine for optimal performance in the operating theatre.
Type: Individual
| Tools & Equipment | Materials |
|---|---|
| Standard Tool Kit (Screwdrivers, Pliers, Allen Keys) | Sticky Notes |
| Disposable Gloves | |
| Dustcoat | |
| Safety Boots | |
| Surgical Mask | |
| Head Gear | |
| Service Manual for Heart Lung Machine |
| S/N | Item | Quantity |
|---|---|---|
| 1 | Heart Lung Machine | 1 Pc per Candidate |
| 2 | Sticky Notes | 6 Pcs per Candidate |
| 3 | Disposable Gloves | 1 Pair per Candidate |
| 4 | Dustcoat | 1 Pc per Candidate |
| 5 | Safety Boots | 1 Pair per Candidate |
| 6 | Surgical Mask | 1 Pc per Candidate |
| 7 | Head Gear | 1 Pc per Candidate |
| 8 | Standard Tool Kit (Screwdrivers, Pliers, Allen Keys) | 1 Pc per Candidate |
| 9 | Service Manual for Heart Lung Machine | 1 Pc per Candidate |
| Items to be Evaluated | Marks Available | Marks Obtained | Comments |
|---|---|---|---|
| TASK 1: WEAR PERSONAL PROTECTIVE EQUIPMENT | |||
| Wore dustcoat (Award 1 mark if worn, 0 if not) | 1 | ||
| Wore safety boots (Award 1 mark if worn, 0 if not) | 1 | ||
| Wore surgical mask (Award 1 mark if worn, 0 if not) | 1 | ||
| Wore head gear (Award 1 mark if worn, 0 if not) | 1 | ||
| Wore disposable gloves (Award 1 mark if worn, 0 if not) | 1 | ||
| Sub-Total | 5 | ||
| TASK 2: IDENTIFY AND LABEL PARTS OF THE HEART LUNG MACHINE | |||
| Identified and labeled oxygenator (Award 1 mark for correct identification) | 1 | ||
| Identified and labeled pump console (Award 1 mark for correct identification) | 1 | ||
| Identified and labeled heat exchanger (Award 1 mark for correct identification) | 1 | ||
| Identified and labeled arterial filter (Award 1 mark for correct identification) | 1 | ||
| Identified and labeled reservoir (Award 1 mark for correct identification) | 1 | ||
| Identified and labeled control panel (Award 1 mark for correct identification) | 1 | ||
| Sub-Total | 6 | ||
| TASK 3: EXPLAIN FUNCTIONS OF IDENTIFIED PARTS | |||
| Explained function of oxygenator (Award 2 marks for accurate explanation) | 2 | ||
| Explained function of pump console (Award 2 marks for accurate explanation) | 2 | ||
| Explained function of heat exchanger (Award 2 marks for accurate explanation) | 2 | ||
| Explained function of arterial filter (Award 2 marks for accurate explanation) | 2 | ||
| Explained function of reservoir (Award 2 marks for accurate explanation) | 2 | ||
| Explained function of control panel (Award 2 marks for accurate explanation) | 2 | ||
| Sub-Total | 12 | ||
| TASK 4: MAINTAIN WORK AREA AND REPORT | |||
| Maintained clean working area after task (Award 1 mark for good housekeeping) | 1 | ||
| Prepared clear service report with date, machine name, observations and procedures (Award up to 2 marks for complete and clear report) | 2 | ||
| Sub-Total | 3 | ||
| PRODUCT CHECKLIST | |||
| Correctly labeled six main parts of the heart lung machine (Award 1 mark per correctly labeled part) | 6 | ||
| Provided accurate explanations for functions of all labeled parts (Award 2 marks per correct function explanation) | 12 | ||
| Sub-Total | 18 | ||
| GRAND TOTAL | 44 | ||
Type: Individual
| Tools & Equipment | Materials |
|---|---|
| Standard tool kit | Disposable gloves |
| Sticky notes | Dust coat |
| Safety boots | |
| Cleaning cloth |
| S/N | Item | Quantity |
|---|---|---|
| 1 | Heart Lung Machine (disassembled) | 1 Pc per Candidate |
| 2 | Sticky notes | 6 Pcs per Candidate |
| 3 | Standard tool kit (screwdrivers, pliers, wrenches) | 1 Set per Candidate |
| 4 | Disposable gloves | 1 Pair per Candidate |
| 5 | Dust coat | 1 Pc per Candidate |
| 6 | Safety boots | 1 Pair per Candidate |
| 7 | Cleaning cloth | 2 Pcs per Candidate |
| Items to be Evaluated | Marks Available | Marks Obtained | Comments |
|---|---|---|---|
| TASK 1: WEAR PERSONAL PROTECTIVE EQUIPMENT | |||
| Wore dust coat (Award 1 mark for wearing dust coat) | 1 | ||
| Wore safety boots (Award 1 mark for wearing safety boots) | 1 | ||
| Wore disposable gloves (Award 1 mark for wearing gloves) | 1 | ||
| Sub-Total | 3 | ||
| TASK 2: IDENTIFY AND LABEL MAIN PARTS OF THE HEART LUNG MACHINE | |||
| Identified and labeled Oxygenator (Award 1 mark for correct identification and label) | 1 | ||
| Identified and labeled Pump Console (Award 1 mark for correct identification and label) | 1 | ||
| Identified and labeled Heat Exchanger (Award 1 mark for correct identification and label) | 1 | ||
| Identified and labeled Control Panel (Award 1 mark for correct identification and label) | 1 | ||
| Identified and labeled Tubing Circuit (Award 1 mark for correct identification and label) | 1 | ||
| Sub-Total | 5 | ||
| TASK 3: ASSEMBLE THE HEART LUNG MACHINE PARTS | |||
| Assembled Oxygenator correctly to Pump Console (Award 2 marks for correct assembly with proper fittings) | 2 | ||
| Connected Heat Exchanger properly within the circuit (Award 2 marks for correct connection and secure fitting) | 2 | ||
| Mounted Control Panel securely on machine frame (Award 1 mark for secure mounting) | 1 | ||
| Arranged Tubing Circuit without kinks or leaks (Award 2 marks for proper tubing arrangement and leak-free assembly) | 2 | ||
| Sub-Total | 7 | ||
| TASK 4: CLEAN AND PREPARE THE MACHINE FOR USE | |||
| Used cleaning cloth to wipe parts before assembly (Award 1 mark for proper cleaning) | 1 | ||
| Maintained clean working area throughout (Award 1 mark for good housekeeping) | 1 | ||
| Sub-Total | 2 | ||
| PRODUCT CHECKLIST | |||
| Assembled Heart Lung Machine dimensions approximately 1200mm length x 800mm width x 1400mm height (Award 2 marks for correct overall dimensions within ±20mm tolerance) | 2 | ||
| All main parts correctly assembled and firmly fixed (Award 3 marks for correct and secure assembly of all labeled parts) | 3 | ||
| No visible damage or loose connections (Award 2 marks for intact and stable final assembly) | 2 | ||
| Sub-Total | 7 | ||
| GRAND TOTAL | 24 | ||
At the start of this chapter we promised you would be able to:
Tick each one you can genuinely do.
So, are you there yet?
You're competent when you can confidently do 50% or more of what this chapter promised.
Sign in to record how you're doing.