Refrigeration And Air Conditioning  ·  Level 5
Domestic Refrigeration Units Installation
Chapter 2: Carry out refrigerant recovery
📚 10 Topics
⚑ What you will be able to do

By the end of this chapter, you will be able to:

  • correctly assemble all the tools, equipment, and materials needed for installing a refrigeration unit following workplace procedures
  • prepare a complete and accurate installation report as required by your workplace
  • prepare the refrigeration unit and its components properly before installation
  • install the refrigeration unit safely and correctly following both workplace procedures and the manufacturer’s specifications
  • install hydrocarbon refrigeration units safely and in full compliance with manufacturer guidelines and relevant safety standards like EN 378, ISO 5149, and EN 13313
  • position and level the refrigeration unit accurately to ensure optimal operation
  • use safe handling techniques for the refrigeration unit according to manufacturer instructions and OSHA safety requirements
  • check and confirm that the electrical voltage and current match the unit’s rated specifications
  • set the temperature controls accurately to meet the user’s needs
  • hand over the refrigeration unit to the user professionally and according to workplace procedures

Mastering these skills ensures you install refrigeration units safely and efficiently, providing reliable cooling that keeps homes and businesses comfortable and running smoothly.

Refrigerant recovery is a critical task for refrigeration and air conditioning professionals in Kenya, especially when servicing domestic refrigeration units. This process involves safely removing refrigerant from a system to prevent environmental damage and to comply with legal requirements. Understanding the types of refrigerants in use is fundamental to effective recovery, as different refrigerants require specific handling techniques due to their chemical properties and environmental impact.

2.1 Type of refrigerant

The choice of refrigerant in domestic refrigeration units affects not only the system’s performance but also the methods used during refrigerant recovery. Kenyan technicians working in households, hotels, and small retail businesses must be familiar with the characteristics of common refrigerants to ensure compliance with environmental regulations such as those enforced by NEMA. Proper identification of refrigerant type also safeguards the technician from health risks and helps maintain system integrity during servicing.

2.1.1 Classification of Refrigerants

Refrigerants are classified based on their chemical composition and environmental impact. Understanding these categories is essential for selecting appropriate recovery procedures and equipment.

Types by Chemical Composition

  • Chlorofluorocarbons (CFCs): These were widely used historically but are now largely banned due to their high ozone depletion potential. An example is R-12, once common in domestic refrigerators.
  • Hydrochlorofluorocarbons (HCFCs): Transitional refrigerants like R-22, which have lower ozone depletion potential than CFCs but are being phased out under international agreements.
  • Hydrofluorocarbons (HFCs): These refrigerants, such as R-134a, do not deplete the ozone layer but have high global warming potential, requiring careful handling and recovery.
  • Natural Refrigerants: Including ammonia (R-717), carbon dioxide (R-744), and hydrocarbons like propane (R-290). These have low environmental impact but may be flammable or toxic, demanding specialized skills.
  • Hydrofluoroolefins (HFOs): Newer refrigerants with low global warming potential, increasingly used in modern domestic refrigeration units.

Environmental Classification

  • Ozone Depleting Substances (ODS): CFCs and HCFCs fall under this category and are subject to strict controls in Kenya.
  • Non-ODS Refrigerants: HFCs and natural refrigerants that do not harm the ozone layer but may contribute to global warming.
  • Low Global Warming Potential Refrigerants: HFOs and some natural refrigerants designed to minimize environmental impact.

2.1.2 Identification Methods for Refrigerants

Correctly identifying the refrigerant type before recovery is crucial for safety and regulatory compliance. Kenyan technicians use several methods to determine the refrigerant in domestic units.

Visual Identification

  • Nameplate and Labels: Most domestic refrigeration units have labels indicating the refrigerant type. For example, a label on a refrigerator at a Nairobi hotel might specify R-134a.
  • Colour Coding: Some manufacturers use colour-coded service ports or tubing to indicate refrigerant type, although this is not standardized.
  • System Components: The design of compressors and expansion valves can hint at the refrigerant type, but this requires experience.

Instrumental Techniques

  • Refrigerant Identifier Devices: Portable analyzers that detect refrigerant type by sampling the gas, useful in fieldwork at county offices or retail shops.
  • Pressure-Temperature Charts: Comparing system pressure and temperature readings to known refrigerant data helps confirm the refrigerant type.
  • Gas Chromatography: Used in laboratories for precise identification, though rarely available on-site.

2.1.3 Properties of Common Refrigerants in Domestic Units

Each refrigerant possesses unique thermodynamic and safety properties that influence how recovery is conducted.

Thermodynamic Properties

  • Boiling Point: Determines the temperature at which the refrigerant evaporates; for example, R-134a boils at -26.3°C, facilitating cooling in domestic refrigerators.
  • Pressure Levels: Operating pressures vary; R-600a (isobutane) operates at lower pressures compared to R-134a, affecting recovery equipment settings.
  • Heat Absorption and Release: Efficiency in absorbing heat during evaporation and releasing it during condensation impacts system performance.

Safety Properties

  • Flammability: Hydrocarbon refrigerants like R-600a are flammable, requiring strict precautions during recovery to prevent accidents in domestic settings.
  • Toxicity: Ammonia is toxic and corrosive, rare in domestic units but important in some commercial refrigeration.
  • Environmental Impact: Ozone depletion potential and global warming potential guide the choice of refrigerant and recovery methods.

2.1.4 Regulatory and Environmental Considerations for Refrigerants in Kenya

Kenyan legislation and international protocols influence refrigerant selection and recovery practices to protect the environment and human health.

Legal Framework

  • Environmental Management and Coordination Act (EMCA): Enforces controls on ozone-depleting substances and mandates proper refrigerant recovery and disposal.
  • NEMA Guidelines: Provide standards for refrigerant handling, recovery, and reporting to prevent illegal venting.
  • International Agreements: Kenya is a signatory to the Montreal Protocol, requiring phase-out of CFCs and HCFCs.

Environmental Impact

  • Ozone Layer Protection: Recovery of CFCs and HCFCs is critical to prevent further ozone depletion.
  • Climate Change Mitigation: Proper recovery of HFCs reduces greenhouse gas emissions, supporting Kenya’s climate action goals.
  • Safe Disposal and Recycling: Recovered refrigerants must be reclaimed or destroyed to avoid environmental contamination, with facilities available in Nairobi and Mombasa.

Practice Questions

  1. Explain the differences between CFCs, HCFCs, and HFCs in terms of chemical composition and environmental impact. (10 marks)
  2. Describe four methods a technician can use to identify the type of refrigerant in a domestic refrigeration unit. (8 marks)
  3. Discuss five thermodynamic and safety properties of refrigerants that affect the refrigerant recovery process. (10 marks)
  4. Outline the key regulatory requirements in Kenya that govern the recovery of refrigerants from domestic refrigeration units. (7 marks)
The rest of this chapter
🔒

Create a free account to open more of this chapter.

Free: practical guides, quick cards, workplace scenarios and more.

Create a free account
🔒2.2 Terms and concepts of refrigerant recovery

Refrigerant recovery is a critical process in refrigeration and air conditioning servicing in Kenya. With increasing environmental regulations such as the Kenya Environmental Management and Coordination Act (EMCA) and global agreements like the Kigali Amendmen…

🔒2.3 Tools, equipment and materials

In the context of refrigerant recovery for domestic refrigeration units in Kenya, the selection and use of appropriate tools, equipment, and materials are critical for efficient, safe, and environmentally compliant operations. Refrigeration technicians working…

🔒2.4 Decommissioning procedures for hydrocarbon RAC systems

In Kenya’s refrigeration and air conditioning (RAC) industry, handling hydrocarbon refrigerants requires strict adherence to safety and environmental protocols during decommissioning. Hydrocarbon refrigerants such as propane (R290) and isobutane (R600a) are in…

🔒2.5 Safe procedures for handling potentially hazardous system materials, including hydrocarbon refrigerants

In the Kenyan refrigeration and air conditioning sector, the transition towards environmentally friendly refrigerants such as hydrocarbons (e.g., propane R290, isobutane R600a) is gaining momentum due to their low global warming potential. However, these refri…

🔒2.6 Calculate the safe fill weight for the recovery cylinder (density difference between HFCs and HCs)

In domestic refrigeration, safe handling of refrigerants during recovery is critical for environmental protection and operator safety. A key skill for refrigeration professionals in Kenya is accurately calculating the maximum safe fill weight for recovery cyli…

🔒2.7 Preparation for recovery

Preparation for refrigerant recovery is a critical phase in the servicing and maintenance of domestic refrigeration units. In Kenya, where environmental regulations such as the Environmental Management and Coordination Act (EMCA) emphasize the protection of th…

🔒2.8 Pressure Testing of the Cylinder

Pressure testing of refrigerant recovery cylinders is an essential safety and maintenance procedure for refrigeration and air conditioning professionals in Kenya. This process ensures the integrity of the recovery cylinder before it is used to store refrigeran…

🔒2.9 Connecting manifold gauge set

In domestic refrigeration units installation and maintenance, connecting the manifold gauge set correctly is essential for effective refrigerant recovery, system diagnosis, and charging. In Kenya, refrigeration technicians working in hospitals, hotels, and ret…

🔒2.10 Performing Refrigerant Recovery

Refrigerant recovery is a critical practice in refrigeration and air conditioning servicing, particularly within domestic refrigeration units. In Kenya, where environmental regulations such as those enforced by NEMA (National Environment Management Authority)…

Chapter Summary

This chapter covers the essential aspects of carrying out refrigerant recovery in domestic refrigeration units, beginning with the identification of different types of refrigerants used in such systems. It explains fundamental terms and concepts related to refrigerant recovery, ensuring clarity before practical work begins. The chapter details the necessary tools, equipment, and materials required to perform safe and effective recovery operations. Special attention is given to decommissioning procedures for hydrocarbon-based refrigeration and air conditioning systems, highlighting the unique challenges they present. Safe handling practices for potentially hazardous materials, including hydrocarbon refrigerants, are emphasized to protect technicians and the environment. The calculation of safe fill weights for recovery cylinders is addressed, focusing on the density differences between hydrofluorocarbon and hydrocarbon refrigerants. Preparation steps for recovery are outlined, followed by procedures for pressure testing the recovery cylinder to ensure its integrity. Finally, the chapter guides the correct connection of the manifold gauge set and the step-by-step process of performing refrigerant recovery, ensuring compliance with safety and environmental standards.

Self-Assessment

🔒 PDFDownload this self-assessment, with answers

A. Written Assessment

  1. What are the main types of refrigerants commonly used in domestic refrigeration units? (2 marks)
  2. Define refrigerant recovery and explain its importance in refrigeration servicing. (3 marks)
🔒20 more in this section.

Chapter Examination Questions

🔒 PDFDownload these examination questions, with worked answers

SECTION A (40 Marks) - Answer ALL Questions

  1. Explain the differences between hydrocarbon and HFC refrigerants commonly used in domestic refrigeration systems in Kenya. (4 marks)
  2. Define the term "refrigerant recovery" and explain its importance in domestic refrigeration maintenance. (4 marks)
🔒18 more in this section.

Chapter Practical Activities

Practical 1: Identify and Classify Types of Refrigerants by Properties

Refrigeration And Air Conditioning · Level 5
Domestic Refrigeration Units Installation
PRACTICAL ASSESSMENT
TIME: 4 HOURS
⬇ PDFCandidate Instructions (Candidate Tool)

Type: Individual

INSTRUCTIONS TO CANDIDATE:
1.  You are required to perform the following task:
i.  Identify and classify refrigerants R134a, R600a, and R22 by type and properties using provided samples and chart.
2.  You have been provided with the following resources for the practical task:
Tools & EquipmentMaterials
Digital Refrigerant ScaleAssorted Refrigerant Samples (R134a, R600a, R22)
Refrigerant Leak DetectorRefrigerant Identification Chart
Manifold Gauge SetRefrigerant Recovery Cylinder (Empty)
Notepad and PenRefrigerant Safety Data Sheets (SDS)
⬇ PDFResources Required (Cutting List)
S/NItemQuantity
1Assorted Refrigerant Samples (R134a, R600a, R22)1 set per Candidate
2Refrigerant Identification Chart1 per Candidate
3Digital Refrigerant Scale1 per Workstation
4Refrigerant Leak Detector1 per Workstation
5Safety Overall1 per Candidate
6Safety Boots1 pair per Candidate
7Protective Gloves1 pair per Candidate
8Refrigerant Recovery Cylinder (Empty)1 per Workstation
9Manifold Gauge Set1 per Workstation
10Refrigerant Safety Data Sheets (SDS)1 set per Candidate
11Notepad and Pen1 per Candidate
⬇ PDFAssessor Guide
Items to be EvaluatedMarks AvailableMarks ObtainedComments
TASK 1: Safety and Preparation
Wore safety overall and safety boots
(Award 1 mark for correct PPE use or zero)
1
Used protective gloves correctly
(Award 1 mark for glove use or zero)
1
Sub-Total2
TASK 2: Identification of Refrigerants
Checked refrigerant labels and Safety Data Sheets
(Award 1 mark for thorough checking or zero)
1
Used refrigerant identification chart to classify refrigerants
(Award 2 marks for correct classification or zero)
2
Measured refrigerant weight using digital scale accurately
(Award 1 mark for correct measurement or zero)
1
Sub-Total4
TASK 3: Handling and Recovery Procedure
Set up manifold gauge and recovery cylinder correctly
(Award 1 mark for correct setup or zero)
1
Purged hoses before refrigerant recovery
(Award 1 mark for purging or zero)
1
Recovered refrigerant safely into recovery cylinder
(Award 2 marks for safe recovery or zero)
2
Sub-Total4
TASK 4: Documentation and Reporting
Recorded refrigerant types and quantities accurately
(Award 2 marks for accurate records or zero)
2
Prepared a clear service report according to workplace procedure
(Award 3 marks for complete report or zero)
3
Sub-Total5
TASK 5: Housekeeping
Disposed of waste and leftover refrigerants safely
(Award 1 mark for proper disposal or zero)
1
Cleaned and stored tools and equipment properly
(Award 1 mark for proper cleaning and storage or zero)
1
Sub-Total2
PRODUCT CHECKLIST
Correct identification and classification of refrigerants matching chart
(Award 5 marks for 100% correct classification or zero)
5
Accurate measurement of refrigerant quantities within ±5% tolerance
(Award 3 marks for accurate measurement or zero)
3
Complete and clear service report with all required details
(Award 5 marks for complete report or zero)
5
Sub-Total13
GRAND TOTAL30
ASSESSMENT OUTCOME:   ☐ Competent    ☐ Not Yet Competent (competent if at least 50%)

Practical 2: Explain key refrigerant recovery terms and concepts using equipment and charts

Refrigeration And Air Conditioning · Level 5
Domestic Refrigeration Units Installation
PRACTICAL ASSESSMENT
TIME: 3 HOURS
⬇ PDFCandidate Instructions (Candidate Tool)

Type: Individual

INSTRUCTIONS TO CANDIDATE:
1.  You are required to perform the following task:
i.  Explain and label at least five key refrigerant recovery terms and concepts using the provided refrigerant recovery unit, manifold gauges, weighing scale, and refrigerant charts.
2.  You have been provided with the following resources for the practical task:
Tools & EquipmentMaterials
Refrigerant recovery unitRefrigerant recovery cylinder
Manifold gauge setRefrigerant identification chart
Digital refrigerant weighing scaleRefrigerant safety data sheet (SDS)
Marker pens
Notebook
⬇ PDFResources Required (Cutting List)
S/NItemQuantity
1Refrigerant recovery unit1 Pc per Candidate
2Manifold gauge set1 Pc per Candidate
3Digital refrigerant weighing scale1 Pc per Candidate
4Refrigerant recovery cylinder1 Pc per Candidate
5Refrigerant identification chart1 Pc per Candidate
6Refrigerant safety data sheet (SDS)1 Pc per Candidate
7Marker pens2 Pcs per Candidate
8Notebook for notes1 Pc per Candidate
9Overall1 Pc per Candidate
10Safety boots1 Pair per Candidate
11Safety goggles1 Pair per Candidate
⬇ PDFAssessor Guide
Items to be EvaluatedMarks AvailableMarks ObtainedComments
TASK 1: Adherence to safety procedures
Wore overall and safety boots
(Award 1 mark for correct PPE worn or zero)
1
Used safety goggles during handling of equipment
(Award 1 mark for use of goggles or zero)
1
Sub-Total2
TASK 2: Demonstrate understanding of refrigerant recovery equipment
Correctly identified parts of the refrigerant recovery unit
(Award 2 marks for correct identification or zero)
2
Correctly connected manifold gauge to recovery unit and cylinder
(Award 2 marks for correct connection or zero)
2
Demonstrated correct use of digital refrigerant weighing scale
(Award 1 mark for correct usage or zero)
1
Sub-Total5
TASK 3: Explain key refrigerant recovery terms and concepts
Explained the meaning of 'recovery', 'recycling', and 'reclamation'
(Award 2 marks for clear explanation or zero)
2
Described the importance of refrigerant purity and contamination
(Award 1 mark for adequate description or zero)
1
Explained the role of recovery cylinders and pressure ratings
(Award 1 mark for correct explanation or zero)
1
Labeled key terms on refrigerant identification chart accurately
(Award 2 marks for accurate labeling or zero)
2
Sub-Total6
TASK 4: Record and report findings
Recorded notes clearly in notebook
(Award 1 mark for clear notes or zero)
1
Prepared a brief verbal report summarizing key refrigerant recovery concepts
(Award 2 marks for clear and accurate report or zero)
2
Sub-Total3
PRODUCT CHECKLIST
Correct labeling of at least five refrigerant recovery terms on chart
(Award 1 mark per correctly labeled term, max 3 marks)
3
Accuracy and clarity of explanations recorded in notebook
(Award up to 3 marks for clarity and accuracy)
3
Proper connection and setup of equipment demonstrated
(Award 4 marks for correct setup as per safety and operational standards)
4
Sub-Total10
GRAND TOTAL26
ASSESSMENT OUTCOME:   ☐ Competent    ☐ Not Yet Competent (competent if at least 50%)
🔒

Free: practical guides, quick cards, workplace scenarios and more.

Create a free account
🔒Select and Prepare Tools, Equipment, and Materials for Refrigerant RecoveryPractical 3
🔒Decommission a Hydrocarbon Domestic Refrigeration Unit 600mm x 600mm x 1700mmPractical 4
🔒Safe Handling and Containment of Hydrocarbon Refrigerants in Domestic Refrigeration UnitsPractical 5
🔒Calculate Safe Fill Weight for Recovery Cylinder with HFC and HC RefrigerantsPractical 6
🔒Prepare and Pressure Test Recovery Cylinder for Refrigerant RecoveryPractical 7
🔒Connect manifold gauge set correctly for refrigerant recoveryPractical 8
🔒Perform Refrigerant Recovery from a Domestic RefrigeratorPractical 9
🔒Perform Full Refrigerant Recovery on Domestic Hydrocarbon Refrigeration UnitPractical 10
Flashcards 20 cards Study deck ▾
Question
1

↻ Tap card to reveal answer
🔒

18 more in this section.

Create a free account
Test Yourself 17 questions Start quiz ▾
0%
0 / 2
🔒

15 more in this section.

Create a free account
Am I competent?

At the start of this chapter we promised you would be able to:

  • correctly assemble all the tools, equipment, and materials needed for installing a refrigeration unit following workplace procedures
  • prepare a complete and accurate installation report as required by your workplace
  • prepare the refrigeration unit and its components properly before installation
  • install the refrigeration unit safely and correctly following both workplace procedures and the manufacturer’s specifications
  • install hydrocarbon refrigeration units safely and in full compliance with manufacturer guidelines and relevant safety standards like EN 378, ISO 5149, and EN 13313
  • position and level the refrigeration unit accurately to ensure optimal operation
  • use safe handling techniques for the refrigeration unit according to manufacturer instructions and OSHA safety requirements
  • check and confirm that the electrical voltage and current match the unit’s rated specifications
  • set the temperature controls accurately to meet the user’s needs
  • hand over the refrigeration unit to the user professionally and according to workplace procedures