Electrical Engineering  ·  Level 6
Trunking System Installation
Chapter 4: Install electrical cables and accessories
📚 7 Topics
⚑ What you will be able to do

By the end of this chapter, you will be able to:

  • Apply safety measures following OSHA and EHS standards to work safely with electrical cables.
  • Identify electrical cable colour codes correctly according to IEC standards.
  • Identify electrical cable sizes accurately following IEC standards.
  • Lay electrical cables correctly in line with IEC standards.
  • Fix electrical accessories accurately following IEC standards.
  • Perform housekeeping activities properly to keep your work area clean and safe.

Mastering these skills ensures you work safely and professionally, making you a valuable electrician who delivers quality installations every time.

Electrical cable installation is a fundamental skill across many professional fields in Kenya, from healthcare facilities to commercial enterprises. Proper identification and sizing of cables ensure safety, efficiency, and compliance with national standards such as the Kenya Bureau of Standards (KEBS) and the Energy and Petroleum Regulatory Authority (EPRA). This chapter focuses on the essential knowledge required to install electrical cables and accessories correctly, emphasizing colour coding and cable sizing to support safe and effective electrical systems in diverse workplaces like county hospitals, universities, banks, and hotels.

4.1 Electrical Cable Colour Code Identification

Colour coding of electrical cables is crucial for safety, maintenance, and troubleshooting in any installation environment. In Kenya, adherence to the prescribed colour code helps electricians and technicians quickly identify the function of each conductor, reducing risks of accidents and ensuring system reliability in institutions such as county government offices and retail businesses.

Purpose of Electrical Cable Colour Coding

Electrical cable colour coding serves multiple safety and operational purposes. It prevents wiring errors that could lead to electrical shocks or equipment damage. For example, at a Nairobi university, proper colour coding enables maintenance staff to isolate circuits safely during repairs, avoiding disruptions to teaching activities.

Importance of Colour Coding
  • Safety Enhancement: Colour coding reduces the risk of electric shock by clearly distinguishing live, neutral, and earth conductors.
  • Ease of Maintenance: Technicians can quickly identify cables during inspections or repairs, limiting downtime in facilities like hospitals.
  • Standard Compliance: Following KEBS and IEC colour standards ensures installations meet legal and technical requirements.
  • System Reliability: Accurate identification prevents incorrect connections that could cause short circuits or fires.
  • Training and Communication: Uniform colour codes facilitate consistent training across different sectors and ease communication among workers.

Standard Colour Codes for Single-Phase Systems

In Kenya, single-phase electrical installations use a standard colour scheme for conductors. Understanding these colours is vital for electricians working in diverse settings such as SACCO offices or agricultural cooperatives.

Standard Colours and Their Functions
  • Red: Live conductor carrying current from the power source to the load.
  • Black: Neutral conductor that completes the circuit back to the power source.
  • Green/Yellow Striped: Earth or protective conductor to prevent electric shocks by grounding faults.
  • Blue: Sometimes used as an alternative neutral conductor in specific installations.
  • Brown: Occasionally used as a phase conductor in newer installations adhering to IEC standards.

Colour Coding in Three-Phase Systems

Three-phase systems, common in larger commercial buildings like hotels and county referral hospitals, use a more complex colour scheme to identify multiple live conductors.

Three-Phase Colour Identification
  • Red, Yellow, Blue: Three live conductors each representing a phase (L1, L2, L3).

Four insulated electrical wires
Four insulated electrical wires (Source: WORKSHOP TECHNOLOGY (electrical)-1)

  • Black: Neutral conductor returning current.
  • Green/Yellow Striped: Protective earth conductor.
  • Grey: Alternative neutral conductor in some installations.

Challenges and Solutions in Colour Code Identification

Despite standardisation, challenges such as colour fading, inconsistent practices, or use of non-standard cables occur on-site, especially in older buildings or informal sectors.

Challenges
  • Faded or Damaged Insulation: Makes identification difficult during maintenance.
  • Non-Standard Cable Usage: Some installers may use cables that do not conform to standards.
  • Mixed Colour Codes: Inherited wiring in renovations may not follow current codes.
  • Lack of Documentation: Absence of wiring diagrams complicates troubleshooting.
  • Training Gaps: Workers unfamiliar with colour standards increase risk of errors.
Solutions
  • Regular Inspections: Scheduled checks in places like county government offices help detect and correct issues.
  • Proper Marking: Use of labels and tags supplements colour codes where fading occurs.
  • Standardised Procurement: Ensuring only KEBS-approved cables are used in institutions such as retail businesses.
  • Training and Awareness: Continuous professional development for electricians and technicians.
  • Updating Wiring Plans: Maintaining accurate and updated wiring diagrams for all installations.

Practice Questions

  1. Explain why electrical cable colour coding is essential in a hospital environment. (5 marks)
  2. Identify the standard colours used for live, neutral, and earth conductors in a single-phase system in Kenya. (6 marks)
  3. Discuss the challenges that may arise when identifying cable colours in older county government offices and propose solutions. (8 marks)
The rest of this chapter
🔒

Create a free account to open more of this chapter.

Free: practical guides, quick cards, workplace scenarios and more.

Create a free account
🔒4.2 Electrical Cable Sizes Identification

Correct identification of electrical cable sizes is fundamental to ensuring that cables carry the required current without overheating or voltage drop. In Kenyan workplaces such as banks, farms, and universities, selecting the right cable size protects equipme…

🔒4.3 Cable Laying

In the installation of electrical cables, laying is a fundamental process that ensures the safe, efficient, and durable placement of cables within various environments. In Kenya, this is particularly relevant in institutions such as county referral hospitals,…

🔒4.4 Electrical Single-Phase Intake Point Installation

In many Kenyan institutions and businesses, the installation of a reliable and safe electrical single-phase intake point is crucial for distributing electricity efficiently. Whether for a county hospital, a university campus, or a retail business, the intake p…

🔒4.5 Electrical Final Circuits Installation

Final circuits form the last stage in an electrical distribution system, delivering power directly to electrical devices and appliances. In Kenya, the installation of final circuits is crucial in diverse settings such as county hospitals, universities, retail…

🔒4.6 Power

Power supply infrastructure forms the backbone of all electrical installations in Kenya's diverse workplaces, from county hospitals to retail businesses. Understanding the types of power outlets and units used in these environments ensures safe and efficient e…

🔒4.7 Housekeeping Activities

Housekeeping is a vital component of any electrical installation project, particularly when installing electrical cables and accessories. Maintaining a clean and organized work environment in Kenyan workplaces such as county government offices, hospitals, and…

Chapter Summary

This chapter covered the identification of electrical cables using colour codes and the recognition of various cable sizes ranging from 1.0mm2 to 6.0mm2, highlighting their specific applications. It explained proper methods for laying cables with a focus on single core cables to ensure safety and functionality. The installation of single-phase intake points was detailed, including the fitting of cut-outs, energy meters, consumer control units, earth rods, and switch fuses. The chapter then addressed the installation of final electrical circuits, discussing lighting configurations such as one way, two way, and intermediate switching, as well as looping in techniques. Power circuit installations were examined with emphasis on socket outlets arranged in ring and radial forms, cooker units, and water heaters. Finally, the importance of housekeeping activities was emphasized, stressing the need for maintaining general cleanliness and proper storage of tools and equipment to support efficient and safe electrical work environments.

Self-Assessment

🔒 PDFDownload this self-assessment, with answers

A. Written Assessment

  1. What is the standard colour code for the live conductor in electrical cables used in Kenya? (2 marks)
  2. Identify two key differences between a 1.5mm² and a 4.0mm² electrical cable in terms of typical applications. (3 marks)
🔒20 more in this section.

Chapter Examination Questions

🔒 PDFDownload these examination questions, with worked answers

SECTION A (40 Marks) - Answer ALL Questions

  1. Explain the significance of the electrical cable colour code in ensuring safety during installations at a county referral hospital. (4 marks)
  2. Identify and describe the key characteristics of a 2.5mm² electrical cable used in wiring a university computer lab. (4 marks)
🔒18 more in this section.

Chapter Practical Activities

Practical 1: Identify and Sort Electrical Cables by Colour Code and Size

Electrical Engineering · Level 6
Trunking System Installation
PRACTICAL ASSESSMENT
TIME: 4 HOURS
⬇ PDFCandidate Instructions (Candidate Tool)

Type: Individual

INSTRUCTIONS TO CANDIDATE:
1.  You are required to perform the following task:
i.  Identify and sort single core electrical cables of sizes 1.0 mm2, 1.5 mm2, 2.5 mm2, 4.0 mm2, and 6.0 mm2 by their standard Kenyan colour codes and label them accordingly.
2.  You have been provided with the following resources for the practical task:
Tools & EquipmentMaterials
Cable cutters1.0 mm2 single core PVC insulated cable
Multimeter1.5 mm2 single core PVC insulated cable
Insulation resistance tester (Megger)2.5 mm2 single core PVC insulated cable
4.0 mm2 single core PVC insulated cable
6.0 mm2 single core PVC insulated cable
Cable identification tags
⬇ PDFResources Required (Cutting List)
S/NItemQuantity
11.0 mm2 single core PVC insulated cable2 Metres per Candidate
21.5 mm2 single core PVC insulated cable2 Metres per Candidate
32.5 mm2 single core PVC insulated cable2 Metres per Candidate
44.0 mm2 single core PVC insulated cable2 Metres per Candidate
56.0 mm2 single core PVC insulated cable2 Metres per Candidate
6Cable identification tags10 Pcs per Candidate
7Cable cutters1 Pc per Candidate
8Insulation resistance tester (Megger)1 Pc per 5 Candidates
9Multimeter1 Pc per Candidate
10Safety gloves1 Pair per Candidate
11Safety boots1 Pair per Candidate
⬇ PDFAssessor Guide
Items to be EvaluatedMarks AvailableMarks ObtainedComments
TASK 1: Identification and Sorting of Electrical Cables
Wore personal protective equipment including safety gloves and safety boots
(Award 2 or 0)
2
Handled and used cable cutters and multimeter correctly
(Award 3 or 0)
3
Identified cable colours according to the Kenyan electrical colour code
(Award 1 mark for each correct colour code identification up to 5)
5
Measured and identified cable sizes correctly using a multimeter or cable gauge
(Award 1 mark for each correctly identified cable size up to 5)
5
Sorted the cables neatly by size and colour in separate bundles
(Award 3 or 0)
3
Labeled each cable bundle clearly with cable size and colour using identification tags
(Award 2 or 0)
2
Sub-Total20
PRODUCT CHECKLIST
Cables correctly identified, sorted, and labelled by colour and size with no errors
(Award 10 or 0)
10
Sub-Total10
GRAND TOTAL30
ASSESSMENT OUTCOME:   ☐ Competent    ☐ Not Yet Competent (competent if at least 50%)

Practical 2: Lay 20 meters of 4.0 mm² single core electrical cables on trunking

Electrical Engineering · Level 6
Trunking System Installation
PRACTICAL ASSESSMENT
TIME: 4 HOURS
⬇ PDFCandidate Instructions (Candidate Tool)

Type: Individual

INSTRUCTIONS TO CANDIDATE:
1.  You are required to perform the following task:
i.  Lay and fix 20 meters of 4.0 mm² single core electrical cable in PVC trunking 25x25 mm along the provided route.
2.  You have been provided with the following resources for the practical task:
Tools & EquipmentMaterials
Spirit level4.0 mm² PVC insulated single core cable
Measuring tape 5 metersPVC trunking 25 mm x 25 mm
Hand screwdriverCable clips for 4.0 mm² cable
Wire stripperWood screws 1 inch
HammerPVC junction box 100 mm x 100 mm
PPE: Safety boots, dustcoat, gloves
⬇ PDFResources Required (Cutting List)
S/NItemQuantity
14.0 mm² PVC insulated single core cable20 meters per Candidate
2PVC trunking 25 mm x 25 mm4 meters per Candidate
3Cable clips for 4.0 mm² cable30 pieces per Candidate
4Wood screws 1 inch20 pieces per Candidate
5PVC junction box 100 mm x 100 mm2 pieces per Candidate
6Spirit level1 per Candidate
7Measuring tape 5 meters1 per Candidate
8Hand screwdriver1 per Candidate
9Wire stripper1 per Candidate
10Hammer1 per Candidate
11PPE: Safety boots, dustcoat, gloves1 set per Candidate
⬇ PDFAssessor Guide
Items to be EvaluatedMarks AvailableMarks ObtainedComments
TASK 1: Laying and fixing single core cables
Wore personal protective equipment: safety boots, dustcoat, gloves
(Award 1 or 0)
1
Handled tools correctly and safely
(Award 2 or 0)
2
Measured cable run length accurately within ±2 mm
(Award 3 or 0)
3
Cut trunking and cable to correct lengths
(Award 2 or 0)
2
Fixed trunking runs straight, level and flush to surface
(Award 3 or 0)
3
Installed cable clips at uniform spacing of 300 mm
(Award 2 or 0)
2
Ensured cable bends are smooth and at 90° where required
(Award 2 or 0)
2
Connected cables neatly inside junction boxes
(Award 2 or 0)
2
Performed housekeeping by cleaning work area after completion
(Award 3 or 0)
3
Sub-Total20
PRODUCT CHECKLIST
Cable run length is exactly 20 meters ±2 mm as per drawing
(Award 3 or 0)
3
Trunking fixed straight, level, and flush to surface as shown on drawing
(Award 4 or 0)
4
Cable bends are neat, smooth, and at 90° with no damage to insulation
(Award 3 or 0)
3
Cable clips are spaced uniformly at approximately 300 mm c/c
(Award 3 or 0)
3
Junction boxes installed at specified locations and securely fixed
(Award 3 or 0)
3
Sub-Total16
GRAND TOTAL36
ASSESSMENT OUTCOME:   ☐ Competent    ☐ Not Yet Competent (competent if at least 50%)
🔒

Free: practical guides, quick cards, workplace scenarios and more.

Create a free account
🔒Install Single-Phase Intake Point with Cut-Out SwitchPractical 3
🔒Install Single-Phase Energy Meter and Consumer Control UnitPractical 4
🔒Installation of Earth Rods for Earthing SystemPractical 5
🔒Fit and connect a single-phase switch fuse on installation board 300mm x 250mmPractical 6
🔒Installation of Lighting Final Circuit with One-Way SwitchingPractical 7
🔒Installation and wiring of a lighting circuit with two-way switchesPractical 8
🔒Install lighting circuit with intermediate switching on installation board 1200mm x 600mmPractical 9
🔒Install power final circuits for ring and radial socket outlet circuitsPractical 10
🔒Install and wire cooker unit final circuit with isolator switchPractical 11
🔒Installation and wiring of water heater final circuit 3000mm x 1500mmPractical 12
🔒Demonstrate Looping-in Wiring Method within a Distribution BoardPractical 13
🔒Perform Housekeeping and Tool Storage after Trunking System InstallationPractical 14
🔒Set Out Cable Routes and Fixing Points for Trunking InstallationPractical 15
Flashcards 20 cards Study deck ▾
Question
1

↻ Tap card to reveal answer
🔒

18 more in this section.

Create a free account
Test Yourself 19 questions Start quiz ▾
0%
0 / 2
🔒

17 more in this section.

Create a free account
Am I competent?

At the start of this chapter we promised you would be able to:

  • Apply safety measures following OSHA and EHS standards to work safely with electrical cables.
  • Identify electrical cable colour codes correctly according to IEC standards.
  • Identify electrical cable sizes accurately following IEC standards.
  • Lay electrical cables correctly in line with IEC standards.
  • Fix electrical accessories accurately following IEC standards.
  • Perform housekeeping activities properly to keep your work area clean and safe.

Tick each one you can genuinely do.

So, are you there yet?

You're competent when you can confidently do 50% or more of what this chapter promised.

Sign in to record how you're doing.