Civil Engineering  ·  Level 6
Structural Analysis Principles II
Chapter 2: Analyse forces in 2D framed structures
📚 3 Topics
⚑ What you will be able to do

By the end of this chapter, you will be able to:

  • Identify composite materials correctly by reading and understanding work specifications.
  • Derive compatibility and equilibrium equations following best engineering practices.
  • Solve problems involving composite materials accurately according to given specifications.
  • Determine forces acting on composite materials correctly based on design requirements.

Mastering these skills will help you confidently analyze and design safe, efficient framed structures in your trade.

Compiled by: Samuel Wachira

Structural analysis of two-dimensional (2D) framed structures is a fundamental skill for civil engineers working on building and infrastructure projects across Kenya. Understanding how forces distribute within these frames ensures safety, serviceability, and economic use of materials. This chapter focuses on the mathematical analysis of 2D framed structures, emphasizing methods to determine internal forces and reactions in pin-jointed and rigid-jointed frames commonly found in buildings, bridges, and other civil engineering works.

2.1 Characteristics of 2D Framed Structures

2D framed structures consist of interconnected elements arranged in a plane, designed to support loads and transfer them safely to foundations. These frames are prevalent in Kenyan construction, from multistory buildings in Nairobi to agricultural storage sheds in rural counties. Understanding their characteristics enables engineers to select appropriate analysis methods and design safe, efficient structures.

2.1.1 Differences between pin-jointed and rigid-jointed frames

Joints are connection points which may be pinned or rigid, influencing force transmission. In a pin-jointed frame, members are connected by pins (or connections that act like pins) that allow the members to rotate freely, so no bending moment passes through the joint and, when loads act only at the joints, each member carries a pure axial force of tension or compression. In a rigid-jointed frame, members are connected so firmly, by welding, bolted end plates or monolithic concrete, that the angle between them stays the same under load, so the joint transfers bending moment and shear as well as axial force. This difference decides how the structure behaves, what it can be made of and how it is analysed. Example: the steel roof trusses of a cereal store for a farmers' cooperative are treated as pin-jointed, while the reinforced concrete frame of its office block is rigid-jointed.

Pin-jointed and rigid-jointed frames compared

Feature Pin-jointed frame Rigid-jointed frame
Joint behaviour Members free to rotate at joints Angles between members stay fixed
Forces in members Axial tension or compression only Axial force, shear force and bending moment
Moment at joints Zero Transferred between members
Stability Needs triangulation (triangles) to be stable Stable without triangles because joints resist rotation
Typical members Slender angles, tubes, timber sections Heavier beams and columns, I-sections, RC members
Typical structures Roof trusses, bridge trusses, towers Portal frames, multi-storey building frames
Analysis Method of joints or sections Moment distribution, slope-deflection, software
Determinacy check m + r = 2j 3m + r = 3j

Static determinacy and indeterminacy

A frame is statically determinate if all internal forces and reactions can be found using equilibrium equations alone. If additional compatibility conditions are needed, the frame is statically indeterminate. This classification influences the choice of analysis method. The checks use m = number of members, r = number of support reactions and j = number of joints.

  • Determinate frames: Simpler to analyze but less common in modern construction.
  • Indeterminate frames: Provide greater stiffness and redundancy but require advanced methods.
  • Pin-jointed check: If m + r = 2j the frame is determinate; if greater, it is indeterminate; if less, it is a mechanism and unstable.
  • Rigid-jointed check: Degree of indeterminacy = (3m + r) − 3j.
  • Redundancy: Extra members or supports in an indeterminate frame give alternative load paths if one part fails.

Worked Examples

Example 1: Pin-jointed truss

Given: A truss has 9 members and 6 joints, with a pin support (2 reactions) and a roller support (1 reaction). Check its determinacy.

m + r = 9 + 3 = 12

2j = 2 × 6 = 12

Answer: m + r = 2j, so the truss is statically determinate.

Example 2: Rigid portal frame

Given: A single-bay portal frame has 3 members (two columns and a beam), 4 joints (two column bases and two knees) and two fixed bases, each giving 3 reactions. Find its degree of indeterminacy.

3m + r = 3 × 3 + 6 = 15

3j = 3 × 4 = 12

Degree of indeterminacy = 15 − 12

Answer: The frame is indeterminate to the third degree.

2.1.2 Examples in trusses and frames

Trusses and frames are the two main families of 2D framed structures. Trusses are triangulated assemblies of straight members, assumed pin-jointed, that span long distances with little material and are used for roofs, bridges and towers. Frames are rigid-jointed assemblies of beams and columns that resist load by bending and are used for buildings, warehouses and portal-framed sheds. Example: a new vocational training centre has a Fink timber truss roof over its classrooms and a steel portal frame over its workshop, where a clear floor is needed for machines.

Common types of trusses

Truss type Description Typical use
King post Central vertical post with two inclined struts Short-span house roofs, up to about 8 m
Queen post Two vertical posts with a straining beam between them Medium-span roofs, about 8 to 14 m
Fink Rafters supported by a W-pattern of struts Common pitched roofs for houses and schools
Pratt Verticals in compression, diagonals in tension Bridges and flat or low-pitch roofs
Howe Diagonals in compression, verticals in tension Timber bridges and roofs
Warren Diagonals only, forming equilateral triangles Bridges, footbridges and long-span roofs

Common types of rigid frames

  • Single-bay portal frame: Two columns rigidly joined to a beam or pitched rafters, giving a clear span for warehouses, garages and factories.
  • Multi-bay portal frame: Several portal frames side by side sharing internal columns, used for large stores and markets.
  • Multi-storey frame: Beams and columns connected rigidly at every floor, the usual structure for office and apartment blocks.
  • Gable frame: A portal frame with sloping rafters forming a pitched roof.
  • Braced frame: A rigid or simple frame with diagonal bracing added to resist lateral loads such as wind.

Choosing between a truss and a frame

  • Span: Trusses span long distances economically; portal frames give clear spans with less depth.
  • Headroom: Frames leave the roof space clear, while trusses take up roof depth.
  • Loads: Trusses carry mainly roof loads at the joints; frames carry floors and moments.
  • Material: Trusses suit timber and light steel; frames suit hot-rolled steel and reinforced concrete.
  • Cost and speed: Prefabricated trusses are quick and cheap for roofs; frames suit multi-storey work.

2.1.3 Geometry and components of 2D frames

2D frames are composed of straight members connected at nodes, forming a planar system. The geometry defines the shape and size of the frame, affecting stiffness and load distribution. The primary components include:

  • Beams: Horizontal members that resist bending and shear loads.

Three types of structural beams in carpentry
Three types of structural beams in carpentry (Source: Wikimedia Commons)

  • Columns: Vertical members designed to carry axial compression and bending.
  • Bracing: Diagonal members added to enhance stability against lateral loads.
  • Supports: Points where the frame transfers loads to the ground, typically pinned or fixed.

2.1.4 Load types acting on 2D frames

Frames in civil engineering are subjected to various loads that induce internal forces, and each load type affects the frame differently, requiring careful analysis to ensure safety:

  • Dead Loads: Permanent loads such as self-weight of members and fixed equipment.
  • Live Loads: Transient loads including occupants, furniture, and movable equipment.
  • Wind Loads: Lateral forces caused by wind pressure, critical in tall or exposed structures.
  • Seismic Loads: Dynamic forces during earthquakes, important in regions of seismic activity such as the Rift Valley.
  • Snow and ice loads: Vertical loads from snow accumulation; in Kenya these apply only to structures at very high altitude, while rainwater ponding and hail are the more common extra roof loads.

2.1.5 Stability and possible failure modes

Stability ensures the frame maintains its geometry under load without collapse, and engineers must evaluate the following risks during design and analysis:

  • Buckling of Columns: Sudden lateral deflection under compression.
  • Member Yielding: Permanent deformation when stresses exceed material limits.
  • Joint Failure: Loss of connection integrity, especially in pinned joints.
  • Overall Collapse: Progressive failure due to instability or overload.
  • Sway instability: Large sideways movement of unbraced frames under lateral load.

Practice Questions

  1. Determine the number of beams, columns, and joints in a simple rectangular 2D frame with two bays and three stories. (5 marks)
  2. Identify the types of loads acting on a 2D frame supporting a typical school building roof in Nairobi. (5 marks)
  3. Classify a given 2D frame as statically determinate or indeterminate based on its support and member arrangement. (6 marks)
The rest of this chapter
🔒

Create a free account to open more of this chapter.

Free: practical guides, quick cards, workplace scenarios and more.

Create a free account
🔒2.2 Assumptions and Methods in Structural Analysis

Structural analysis relies on simplifying assumptions to model complex real-world behavior mathematically. These assumptions define the behavior of members and joints, enabling engineers to apply appropriate methods for calculating forces and displacements in…

🔒2.3 Analysis of Real-World 2D Frames

In Kenyan civil engineering practice, 2D framed structures are widely used in buildings, bridges, and industrial sheds. Accurately analyzing forces in these frames ensures safety and economy in design, especially under varying loads such as wind, live loads, a…

Chapter Summary

This chapter explored the characteristics of two-dimensional framed structures, highlighting the fundamental differences between pin-jointed and rigid-jointed frames and illustrating these concepts through examples in trusses and frames. It then examined the key assumptions and methods used in structural analysis, focusing on the method of joints and the method of sections as primary techniques for evaluating internal forces. The chapter proceeded to analyze real-world 2D frames by demonstrating how to calculate forces in truss members and determine support reactions for various frame types. Practical application was emphasized through detailed examples involving roof trusses and portal frames, showing how theoretical principles translate into structural design and assessment. Throughout the chapter, the integration of theory with practice reinforced the importance of accurate force analysis in ensuring the stability and safety of framed structures.

Self-Assessment

🔒 PDFDownload this self-assessment, with answers

Written Assessment

  1. A simple 2D pin-jointed truss has a horizontal top chord member of length 6 m and a vertical member of length 4 m forming a right angle. Calculate the length of the diagonal member connecting the bottom left joint to the top right joint. (2 marks)

  2. A roof truss is supported at two points 8 m apart. The truss carries a uniformly distributed load of 12 kN/m along the top chord. Calculate the vertical reaction at each support. (3 marks)

🔒18 more in this section.

Chapter Examination Questions

🔒 PDFDownload these examination questions, with worked answers

SECTION A (40 Marks) - Answer ALL Questions

  1. A roof truss in a residential building in Nakuru is constructed as a pin-jointed frame. Identify two key characteristics of pin-jointed frames that affect force distribution in the truss. (4 marks)
  2. Explain how a rigid-jointed frame differs from a pin-jointed frame in terms of moment transfer and deformation. (4 marks)
🔒18 more in this section.
Flashcards 20 cards Study deck ▾
Question
1

↻ Tap card to reveal answer
🔒

18 more in this section.

Create a free account
Test Yourself 16 questions Start quiz ▾
0%
0 / 2
🔒

14 more in this section.

Create a free account
Am I competent?

At the start of this chapter we promised you would be able to:

  • Identify composite materials correctly by reading and understanding work specifications.
  • Derive compatibility and equilibrium equations following best engineering practices.
  • Solve problems involving composite materials accurately according to given specifications.
  • Determine forces acting on composite materials correctly based on design requirements.

Tick each one you can genuinely do.

So, are you there yet?

You're competent when you can confidently do 50% or more of what this chapter promised.